Assembly (Group A) – places used for people gathering for entertainment, worship, and eating or drinking. Examples: churches, restaurants (with 50 or more possible occupants), theaters, and stadiums.

What is a Group B occupancy?

Business Group B occupancy includes, among others, the use of a building or structure, or a portion thereof, for office, professional or service-type transactions, including storage of records and accounts. Business occupancies shall include, but not be limited to, the following: Airport traffic control towers.

What are the different types of occupancy?

  • Group A [Assembly]
  • Group B [Business]
  • Group C [Camps]
  • Group E [Education]
  • Group F [Factory]
  • Group H [High Hazard]
  • Group I [Institutions]
  • Group M [Mercantile]

What is a group R-2 occupancy?

Group R is divided into four sub groups, R-1 occupants are transient in nature, R-2 occupancies containing sleeping units or more than two dwelling units where the occupants are more permanent in nature, R-3 one and two family dwelling, or adult and child care facilities that provide accommodation for five or fewer …

What is occupancy Type R-3?

R-3 Residential occupancies where the occupants are primarily permanent in nature and not classified as Group R-1, R-2, R-2.1, R-4 or I, including: Buildings that do not contain more than two dwelling units. Adult care facilities that provide accommodations for six or fewer clients of any age for less than 24 hours.

What is S 1 occupancy?

Group S-1: Buildings occupied for storage uses that are not classified as a Group S-2 occupancy. A Group S-1 occupancy is also known as a moderate-hazard storage occupancy.

What is an r1 occupancy?

Residential Group R-1 occu- pancies containing sleeping units where the occupants are. primarily transient, including: Hotels. Motels.

What is an R-4 occupancy?

R-4 Residential occupancies shall include buildings arranged for occupancy as residential care/assisted living facilities including more than five but not more than 16 occupants, excluding staff.

What is an I 4 occupancy?

Institutional Group I-4 occupancy shall include buildings and structures occupied by more than five persons of any age who receive custodial care for fewer than 24 hours per day by persons other than parents or guardians, relatives by blood, marriage or adoption, and in a place other than the home of the person cared …

What is an I 3 occupancy?

Institutional Group I-3 occupancy shall include buildings and structures that are inhabited by more than five persons who are under restraint or security. A Group I-3 facility is occupied by persons who are generally incapable of self-preservation due to security measures not under the occupants’ control.

Article first time published on

What is a residential occupancy?

Residential occupancy means the occupancy or use of a building, or part thereof, by persons for whom sleeping accommodation is provided but who are not harboured or detained to receive medical care or treatment or are not involuntarily detained.

What is structure type B?

Class B: Reinforced Concrete Frame Class B buildings are fire-resistant structures. Floors and roofs in class B structures are formed or precast concrete slabs. The exterior walls, generally, are masonry or reinforced concrete curtain walls or any of the many types of wall panels of concrete, metal, glass or stone.

What is a mixed occupancy?

A mixed-occupancy condition occurs where two or more distinct occupancy classifications are determined to exist in the same building. ▪ Under such circumstances, the designer has available several different methodologies in Section 508 to address the mixed-occupancy building. ▪

What is a 2 occupancy?

Group A-2 occupancy includes assembly uses intended for food and/or drink consumption including, but not limited to: Banquet halls; Casinos (gaming areas); Nightclubs; Restaurants, cafeterias and similar dining facilities (including associated commercial kitchens); Taverns and bars.

What is a Group H occupancy?

High-hazard Group H occupancy includes, among others, the use of a building or structure, or a portion thereof, that involves the manufacturing, processing, generation or storage of materials that constitute a physical or health hazard in quantities in excess of those allowed in control areas constructed and located as …

What is IBC construction type?

The 5 types of construction classifications are: Type I, Type II, Type III, Type IV, & Type V. Type I Construction requires the highest fire-resistance rating whereas Type V Construction requires the least amount of fire-resistance rating.

What is construction type?

Building elements like the structure, walls, floors, and roof are all telling of a building’s class. … Buildings can be categorized into five different types of construction: fire-resistive, non-combustible, ordinary, heavy timber, and wood-framed.

What occupancy is a bar?

AreaOccupancyBar (bar seats)29Bar Dining (adjacent seating)65Dining Room45VIP Room12

What is IECC group R?

Residential Group R includes, among others, the use of a building or structure, or a portion thereof, for sleeping purposes when not classified as an Institutional Group I or when not regulated by the International Residential Code.

What is considered occupancy?

Occupancy is living in or using premises or property as a tenant or owner. This includes someone who lives in or uses abandoned property with the intention of acquiring ownership. … The lack of occupancy in this sense is a vacancy.

What is institutional occupancy?

Institutional occupancy means asylums, mental hospitals, hospitals, sanitariums, homes for the aged, residential health care facilities, children’s homes or institutions, or any similar institutional occupancy.

What is Property Type C?

A Class C property is one that is older (typically 30+ years old), in fair to poor condition, and typically not as well-located as a Class A or Class B building. They are considered to be the “riskiest” investment, but in turn, offer some of the best potential cash-on-cash returns.

What is construction type D?

Class D buildings generally have wood frame, floor and roof structure. They are considered combustible construction. This class also includes the pre-engineered pole- or post-frame, hoop and arch-rib-frame buildings. … Floors and roofs are supported on wood or steel joists or trusses.

What is a Type 2 building?

TYPE II – This type of building has steel or concrete walls, floors, and structural framework similar to type I construction; however, the roof covering material is combustible. The roof covering of a type II building can be a layer of asphalt waterproofing, with a combustible felt paper covering.

What is a separated occupancy?

Buildings that contain multiple occupancies must either be considered non-separated or separated. … Separated occupancies, as defined in IBC Section 508.4, require different occupancies to be separated using rated walls (fire barriers per IBC Section 707) and floors/ceilings (horizontal assemblies per IBC Section 711).

What is accessory occupancy?

Accessory occupancies are those occupancies that are ancillary to the main occupancy of the building or portion thereof.

What is an accessory shed?

A shed is an accessory building if it is located on the same lot of land as the house and is used by its occupants. Cargo storage and trailer storage are not considered accessory buildings.